How Does a Distributed Temperature Sensing System Work?
Published:October 18, 2024

The working principle of a Distributed Temperature Sensing (DTS) system is based on Raman scattering and Optical Time Domain Reflectometry (OTDR) in optical fiber. Understanding these two effects explains how a single fiber reports temperature at thousands of points simultaneously.

Raman scattering: the temperature signal. When a laser pulse travels through the fiber, it collides inelastically with the fiber molecules and generates Raman backscatter, which consists of Stokes and Anti-Stokes components. The intensity ratio of the two components depends exponentially on temperature: as temperature rises, the Anti-Stokes intensity increases while the Stokes intensity stays nearly constant. Measuring this ratio therefore yields the absolute temperature at the scattering point.

OTDR: the position signal. By measuring the round-trip time of the light pulse, the system determines where along the fiber each backscattered photon originated. Combining time-domain positioning with Raman thermometry produces a spatially resolved temperature profile along the whole fiber.

Working process. The DTS host unit emits a narrow, wavelength-stable light pulse; the pulse is scattered as it travels; part of the backscatter returns to the photodetector; time-domain analysis assigns each signal to its fiber position; the Stokes and Anti-Stokes power levels are measured; and the calibrated intensity ratio converts the power distribution into a temperature profile along the fiber.

Typical performance and applications. Industrial-grade systems cover -200℃ to +600℃ with a spatial resolution of 0.5 m to 4 m and response times of 10 s to 300 s, immune to electromagnetic interference. With these characteristics, DTS is applied to power cables, pipelines, tunnels, conveyor belts and industrial processes. If you are evaluating a DTS system for your application, contact DSC for a configuration proposal based on your required range, resolution and response time.