The performance of a distributed fiber optic temperature sensing (DTS) system is described by a set of key parameters: temperature resolution, spatial resolution and measurement distance, among others. Understanding each one is the basis for specifying a system correctly.
Temperature resolution. Definition: the smallest temperature change the system can detect, reflecting its sensitivity and accuracy. Reference figure: distributed fiber temperature systems can reach a temperature resolution of 0.01℃ - meaning the system detects temperature changes as small as 0.01℃ at every point along the fiber.
Spatial resolution. Definition: the minimum distance between two adjacent temperature measurement points that the system can distinguish, reflecting its ability to resolve the temperature distribution spatially. Reference figure: spatial resolution can reach within 1 meter, locating temperature changes precisely along each meter of fiber.
Measurement distance. Definition: the total fiber length the system can measure, reflecting coverage and monitoring capability. Reference figure: measurement distances of several kilometers and beyond are standard - long-range DTS configurations reach 10 km and more, and DSC's DSC-DTSmK-nC platform spans 2-30 km in standard configurations with BOTDA systems extending beyond 50 km.
Other parameters. Optical pulse width shapes the theoretical spatial resolution limit; sampling resolution sets the measurement point density; and response time determines how quickly anomalies are reported - the parameters DSC documents in full for each system configuration.
When comparing DTS systems, read the parameters against your actual monitoring requirement - range, resolution and response time trade off against one another. Contact DSC for the specification sheet and configuration advice for your application.